Safety Evaluation of Parallel, Standby, and NMR Systems
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F14%3A00076779" target="_blank" >RIV/00216224:14330/14:00076779 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Safety Evaluation of Parallel, Standby, and NMR Systems
Original language description
Safety instrumented systems and emergency shutdown systems are extremely important for the management and reduction of risk in industry. New standards on functional safety of systems (e.g. [1]) often require a quantification of the achieved safety. Markov model has been known as a strong tool for modeling and evaluation of safety. In this article, we will provide a closed-form solution for computation of safety of parallel, standby, and NMR systems, given the reliability of these systems.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JC - Computer hardware and software
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Deterioration, Dependability, Diagnostics 2014
ISBN
9788072319695
ISSN
—
e-ISSN
—
Number of pages
7
Pages from-to
61-67
Publisher name
University of Defence
Place of publication
Brno, Czech Republic
Event location
University of Defence, Brno, Czech Republic
Event date
Oct 7, 2014
Type of event by nationality
EUR - Evropská akce