The reliability, validity and usefulness of the 30–15 intermittent fitness test for cardiorespiratory fitness assessment in military personnel
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14510%2F22%3A00129824" target="_blank" >RIV/00216224:14510/22:00129824 - isvavai.cz</a>
Result on the web
<a href="https://trebuchet.public.springernature.app/get_content/cd69a714-3da2-4c90-b35e-e5ea80491ad5" target="_blank" >https://trebuchet.public.springernature.app/get_content/cd69a714-3da2-4c90-b35e-e5ea80491ad5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-022-20315-3" target="_blank" >10.1038/s41598-022-20315-3</a>
Alternative languages
Result language
angličtina
Original language name
The reliability, validity and usefulness of the 30–15 intermittent fitness test for cardiorespiratory fitness assessment in military personnel
Original language description
1o.:ȋͬͭͮͯͰͱͲͳScientific Reports | (2022) 12:16087 | https://doi.org/10.1038/s41598-022-20315-3www.nature.com/scientificreports The reliability, validity and usefulness of the 30–15 intermittent fitness test for cardiorespiratory fitness assessment in military personnel Armin H. Paravlic1,2,3*, Bostjan Simunic2 , Rado Pisot2 , Samo Rauter1 , Stanko Stuhec1 & Janez Vodicar1 The objectives of this study were to investigate the reliability, validity, and usefulness of the 30–15 intermittent fitness test (30–15IFT) in soldiers. The 34 infantry members of the Slovenian armed forces were recruited as participants. Participants performed the continuous incremental treadmill test (TR), a 2-mile run (2 MR ) test, and two 30–15IFT tests. Additionally, participants were divided into a highest-scoring group (HSG) and a lowest-scoring group (LSG) based on their scores on the Army Physical Fitness Test. A very high reliability ratings were observed for 30–15IFT measures, as follows: end-running speed (ERS) ERSIFT (ICC = 0.971) , maximal heart rate (HR max ) HR maxIFT (IC = 0.960) , and maximal relative oxygen consumption (VO 2max ) VO2max-IFT (ICC = 0.975) . Although 30–15IFT measures demonstrated high correlations (r = 0.695–0.930) to the same measures of TR test, ERS, HR max and VO2max were higher in the 30–15IFT (p > 0.05) . Furthermore, ERSIFT and predicted VO 2maxIFT were higher in HSG compared to LSG, whereas HR max did not differ. The results of this study show that the 30–15IFT test is a reliable, valid and useful tool for assessing cardiorespiratory fitness in the armed forces. Moreover, the ERS and predicted VO 2 max values derived from the 30–15IFT could be considered more sensitive markers of combat readiness than the parameters derived from the TR and 2 MR tests.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30306 - Sport and fitness sciences
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
SCIENTIFIC REPORTS
ISSN
2045-2322
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
1
Country of publishing house
CH - SWITZERLAND
Number of pages
8
Pages from-to
—
UT code for WoS article
000860850600067
EID of the result in the Scopus database
2-s2.0-85138943494