All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Behaviour of analytical spectral lines emitted by plasma pencil operated in a continuous and in a pulsed mode

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00064558" target="_blank" >RIV/00216224:14740/12:00064558 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.spektroskopia.sk/esas-scsc/BoA.pdf" target="_blank" >http://www.spektroskopia.sk/esas-scsc/BoA.pdf</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Behaviour of analytical spectral lines emitted by plasma pencil operated in a continuous and in a pulsed mode

  • Original language description

    A modification of operating conditions by introduction of an admixture into the plasma gas stream was done for analytical application of plasma pencil ? chemical analysis. Excitation capabilities using sets of standard water solutions containing Na+, Li+, Ca2+, Mg2+, Cu2+ and Zn2+ ions, construction of calibration dependences in the range 1?100 mg/l and calculation of instrumental detection limits for these elements (3-sigma) were done in the continuous and in the pulse mode. Aqueous solution of calibration standard (0.6 ml/min) was delivered into a Scott chamber with a concentric nebulizer with efficiency of about 6 %. The produced aerosol was introduced by argon (0.3 l/min) perpendicularly into the plasma pencil operated in flowing argon (4 l/min). Electrical input power in the range of 120?140 W coming into the plasma guaranteed a stability of the discharge with water and sample load. To create a pulsed mode a carrying wave 13.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    CA - Inorganic chemistry

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: Central european institute of technology</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů