Test-Retest Reproducibility of Neurochemical Profiles with Short-Echo, Single-Voxel MR Spectroscopy at 3T and 7T

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F16%3A00092578" target="_blank" >RIV/00216224:14740/16:00092578 - isvavai.cz</a>

  • Result on the web

    <a href="http://onlinelibrary.wiley.com/doi/10.1002/mrm.26022/epdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/mrm.26022/epdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/mrm.26022" target="_blank" >10.1002/mrm.26022</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Test-Retest Reproducibility of Neurochemical Profiles with Short-Echo, Single-Voxel MR Spectroscopy at 3T and 7T

  • Original language description

    Purpose: To determine the test-retest reproducibility of neurochemical concentrations obtained with a highly optimized, short-echo, single-voxel proton MR spectroscopy (MRS) pulse sequence at 3T and 7T using state-of-the-art hardware. Methods: A semi-LASER sequence (echo time = 26-28 ms) was used to acquire spectra from the posterior cingulate and cerebellum at 3T and 7T from six healthy volunteers who were scanned four times weekly on both scanners. Spectra were quantified with LCModel. Results: More neurochemicals were quantified with mean Cramer-Rao lower bounds (CRLBs) &lt;= 20% at 7T than at 3T despite comparable frequency-domain signal-to-noise ratio. Whereas CRLBs were lower at 7T (P&lt;0.05), between-session coefficients of variance (CVs) were comparable at the two fields with 64 transients. Five metabolites were quantified with between-session CVs &lt;= 5% at both fields.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FH - Neurology, neuro-surgery, nuero-sciences

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: Central european institute of technology</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    MAGNETIC RESONANCE IN MEDICINE

  • ISSN

    0740-3194

  • e-ISSN

  • Volume of the periodical

    76

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    9

  • Pages from-to

    1083-1091

  • UT code for WoS article

    000388618400006