Optimization of anodic stripping voltammetry conditions for efficient detection of quantum dots at micro flow-cell electrodes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911188" target="_blank" >RIV/00216275:25310/17:39911188 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1007/s00706-017-1922-z" target="_blank" >http://dx.doi.org/10.1007/s00706-017-1922-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-017-1922-z" target="_blank" >10.1007/s00706-017-1922-z</a>
Alternative languages
Result language
angličtina
Original language name
Optimization of anodic stripping voltammetry conditions for efficient detection of quantum dots at micro flow-cell electrodes
Original language description
Micro flow-cell screen-printed electrodes were used for single and simultaneous electrochemical detection of core–shell CdSe/ZnS and core-type PbS quantum dots as newly emphasized nanolabels of antibodies in electrochemical immunosensors. Analysis in flow-cell arrangement ensures increased accumulation of Cd(II) and Pb(II) ions released from such quantum dots after acidic dissolution. The optimizations in terms of flow rate and regulation were performed. Conditions of electrochemical detection, concretely deposition potential and time, conditional time, and necessity of working electrode pretreatment were optimized. Such conditions enable simultaneous analysis of Cd(II) and Pb(II) ions released from CdSe/ZnS and PbS quantum dots at micro flow-cell screen-printed electrode without peak overlaps.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10620 - Other biological topics
Result continuities
Project
<a href="/en/project/GA15-16549S" target="_blank" >GA15-16549S: Development of ultrasensitive magneto-immunoassay based on quantum dots/antibody probes for simultaneous electrochemical detection of cancer markers.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Monatshefte fur Chemie
ISSN
0026-9247
e-ISSN
—
Volume of the periodical
148
Issue of the periodical within the volume
3
Country of publishing house
AT - AUSTRIA
Number of pages
5
Pages from-to
"571–575"
UT code for WoS article
000396528600024
EID of the result in the Scopus database
—