Reduction behavior of insecticide azoxystrobin and its voltammetric determination using silver solid amalgam electrode
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914582" target="_blank" >RIV/00216275:25310/19:39914582 - isvavai.cz</a>
Alternative codes found
RIV/61989592:15310/19:73598183
Result on the web
<a href="https://link.springer.com/article/10.1007%2Fs00706-018-2348-y" target="_blank" >https://link.springer.com/article/10.1007%2Fs00706-018-2348-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-018-2348-y" target="_blank" >10.1007/s00706-018-2348-y</a>
Alternative languages
Result language
angličtina
Original language name
Reduction behavior of insecticide azoxystrobin and its voltammetric determination using silver solid amalgam electrode
Original language description
Electrochemical reduction of systemic fungicide azoxystrobin, used to protect a wide variety of crops, was investigated using cyclic voltammetry with a mercury meniscus-modified silver solid amalgam electrode (m-AgSAE). The mechanism of the electrochemical reduction was proposed and supported with high-performance liquid chromatography/mass spectrometry analysis of azoxystrobin solutions electrolyzed on mercury pool electrode. An analytical method for the determination of azoxystrobin by differential pulse voltammetry with m-AgSAE was developed. A wide linear dynamic range (2.0x10(-6)-5.0x10(-5)moldm(-3)) and low limit of detection (7x10(-7)moldm(-3)) were obtained. The accuracy and repeatability of the proposed method were evaluated by the analysis of model solutions with recovery from 96.0 to 104.0% and relative standard deviation of 5 repeated determinations<3.5%. Finally, a new voltammetric method using m-AgSAE was successfully applied for azoxystrobin determination in real samples, concretely in spiked river water and pesticide preparations. [GRAPHICS] .
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA17-03868S" target="_blank" >GA17-03868S: New Methods of Electrochemical Monitoring of Biologically Active Organic Compounds in Environmental, Biological and Food Matrices</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Monatshefte fur Chemie
ISSN
0026-9247
e-ISSN
—
Volume of the periodical
150
Issue of the periodical within the volume
3
Country of publishing house
DE - GERMANY
Number of pages
10
Pages from-to
419-428
UT code for WoS article
000461394400008
EID of the result in the Scopus database
—