All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion (R)

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914606" target="_blank" >RIV/00216275:25310/19:39914606 - isvavai.cz</a>

  • Result on the web

    <a href="https://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800646" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800646</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elan.201800646" target="_blank" >10.1002/elan.201800646</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion (R)

  • Original language description

    A new voltammetric method for simultaneous determination of caffeine and pyridoxine present in different types of commercial energy drinks has been developed. This electroanalytical method is based on anodic oxidation of these biologically active nitrogen-containing heterocycles at glassy carbon electrode covered with thin layer of sulfonated fluoropolymer Nafion® using differential pulse voltammetry in 0.1 M Britton-Robinson buffer of pH 4.5 at potential step 5 mV, potential amplitude 70 mV, and scan rate 50 mV/s. Linear ranges for caffeine and pyridoxine determination were 63.1-600 µM and 7.5-200 µM with the detection limits of 18.9 and 2.2 µM, respectively. It was validated using high-performance liquid chromatography with spectrophotometric detection. Obtained results have shown that voltammetric approach is very simple and low-cost analytical method which can be used for routine determination of caffeine and pyridoxine in energy drinks.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electroanalysis

  • ISSN

    1040-0397

  • e-ISSN

  • Volume of the periodical

    31

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    6

  • Pages from-to

    1511-1516

  • UT code for WoS article

    000479081100012

  • EID of the result in the Scopus database