Fractionation of Enriched Phosphopeptides Using pH/Acetonitrile-Gradient-Reversed-Phase Microcolumn Separation in Combination with LC-MS/MS Analysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F20%3A39916593" target="_blank" >RIV/00216275:25310/20:39916593 - isvavai.cz</a>
Alternative codes found
RIV/60162694:G44__/20:00555944
Result on the web
<a href="https://www.mdpi.com/1422-0067/21/11/3971/htm" target="_blank" >https://www.mdpi.com/1422-0067/21/11/3971/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ijms21113971" target="_blank" >10.3390/ijms21113971</a>
Alternative languages
Result language
angličtina
Original language name
Fractionation of Enriched Phosphopeptides Using pH/Acetonitrile-Gradient-Reversed-Phase Microcolumn Separation in Combination with LC-MS/MS Analysis
Original language description
Mass spectrometry (MS) is a powerful and sensitive method often used for the identification of phosphoproteins. However, in phosphoproteomics, there is an identified need to compensate for the low abundance, insufficient ionization, and suppression effects of non-phosphorylated peptides. These may hamper the subsequent liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) analysis, resulting in incomplete phosphoproteome characterization, even when using high-resolution instruments. To overcome these drawbacks, we present here an effective microgradient chromatographic technique that yields specific fractions of enriched phosphopeptides compatible with LC-MS/MS analysis. The purpose of our study was to increase the number of identified phosphopeptides, and thus, the coverage of the sample phosphoproteome using the reproducible and straightforward fractionation method. This protocol includes a phosphopeptide enrichment step followed by the optimized microgradient fractionation of enriched phosphopeptides and final LC-MS/MS analysis of the obtained fractions. The simple fractionation system consists of a gas-tight microsyringe delivering the optimized gradient mobile phase to reversed-phase microcolumn. Our data indicate that combining the phosphopeptide enrichment with the microgradient separation is a promising technique for in-depth phosphoproteomic analysis due to moderate input material requirements and more than 3-fold enhanced protein identification.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/NV19-02-00297" target="_blank" >NV19-02-00297: Proteomic analysis of the potential markers in patients with dilated cardiomyopathy</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Molecular Sciences
ISSN
1661-6596
e-ISSN
—
Volume of the periodical
21
Issue of the periodical within the volume
11
Country of publishing house
CH - SWITZERLAND
Number of pages
14
Pages from-to
3971
UT code for WoS article
000543400300233
EID of the result in the Scopus database
2-s2.0-85085895215