High-Frequency TiO2 Nanotube-Adapted Microwave Coplanar Waveguide Resonator for High-Sensitivity Ultraviolet Detection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F22%3A39919094" target="_blank" >RIV/00216275:25310/22:39919094 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/22:PU143967
Result on the web
<a href="https://pubs.acs.org/doi/10.1021/acsami.1c21741" target="_blank" >https://pubs.acs.org/doi/10.1021/acsami.1c21741</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acsami.1c21741" target="_blank" >10.1021/acsami.1c21741</a>
Alternative languages
Result language
angličtina
Original language name
High-Frequency TiO2 Nanotube-Adapted Microwave Coplanar Waveguide Resonator for High-Sensitivity Ultraviolet Detection
Original language description
Ultraviolet (UV) sensors are a key component in growing applications such as water quality treatment and environmental monitoring, with considerable interest in their miniaturization and enhanced operation. This work presents a passive gold coplanar waveguide split ring resonator integrated with anodic self-organized TiO2 nanotube (TNT) membranes with a thickness of 20 mu m to provide real-time UV detection. The resonator operated as a one-port device to capture the reflection coefficient (S11) signal, with a center frequency of 16 GHz and a notch amplitude of -88 dB. It was experimentally analyzed for its UV sensing capability in the range of 36.5-463 mu W/cm(2). The high-frequency resonator was improved through design choices including the addition of a tapered input transmission line, wire bonding for practical device design, and an interdigitated capacitive ring gap. The high frequency also helped mitigate noise due to water vapor or environmental contaminants. S11 amplitude variation was found through both experiments and modeling to follow a linear trend with UV illumination intensity. The resonator exhibited over 45 +/- 2 dB shift in the resonant amplitude under the highest UV illumination conditions, with a sensitivity of 0.084 dB/mu W cm(-2) and the potential to sense UV intensity as low as 2.7 mu W/cm(2). The presented device enabled a repeatable and accurate microwave response under UV illumination with very high sensitivity, entirely through the use of passive circuit elements.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
21001 - Nano-materials (production and properties)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
ACS Applied Materials & Interfaces
ISSN
1944-8244
e-ISSN
1944-8252
Volume of the periodical
14
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
6203-6211
UT code for WoS article
000757945500001
EID of the result in the Scopus database
2-s2.0-85124056052