Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F25%3A39922832" target="_blank" >RIV/00216275:25310/25:39922832 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.jpba.2025.116831" target="_blank" >https://doi.org/10.1016/j.jpba.2025.116831</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2025.116831" target="_blank" >10.1016/j.jpba.2025.116831</a>
Alternative languages
Result language
angličtina
Original language name
Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
Original language description
Monitoring patients with phenylketonuria (PKU) requires accurately measuring phenylalanine and tyrosine levels in a small volume of blood samples obtained by the dried blood spot (DBS) technique. The aim was to study selected parameters influencing the quantitative results. Phenylalanine and tyrosine were extracted from DBS samples with methanol, and 5 internal standard introduction techniques were tested. Phenylalanine and tyrosine levels were measured in 6-mm discs punched from DBS, pre-punched 9-mm discs containing the entire DBS sample, and liquid blood by HPLC-MS-MS. Levels in 6-mm discs punched from DBS measured by HPLC-MS/MS were compared with those measured by the HPLC-FLD. The analytical parameters of the method are satisfactory, linearity in the range of 25–1200 μmol/L (LOD, LOQ and LLOQ values 0.2 μmol/L, 0.5 μmol/L and 3.8 μmol/L for phenylalanine, 0.5 μmol/L, 1.5 μmol/L and 5.1 μmol/L for tyrosine), within-run precision 1.8 %–3.7 % for phenylalanine, 1.9 %–2.7 % for tyrosine, between-run precision 4.7 %–5.9 % for phenylalanine, 4.1 %–5.4 % for tyrosine, recovery 93.8 %–100.4 % for phenylalanine and 93.7 %–99.1 % for tyrosine. Good agreement was found between phenylalanine and tyrosine concentrations in 6-mm discs punched from DBS (R = 0.896, p < 0.001, and R = 0.907, p < 0.001, respectively), pre-punched 9-mm discs containing the entire DBS sample (R = 0.960, p < 0.001, and R = 0.950, p < 0.001, respectively) and liquid blood, as well as between phenylalanine and tyrosine concentrations obtained by HPLC-MS/MS and HPLC-FLD (R = 0.968, p < 0.001, and R = 0.984, p < 0.001, respectively). The presented method is suitable for monitoring patients with PKU.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
1873-264X
Volume of the periodical
260
Issue of the periodical within the volume
August 2025
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
116831
UT code for WoS article
001454117200001
EID of the result in the Scopus database
2-s2.0-105000487145