All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F25%3A39922832" target="_blank" >RIV/00216275:25310/25:39922832 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.jpba.2025.116831" target="_blank" >https://doi.org/10.1016/j.jpba.2025.116831</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jpba.2025.116831" target="_blank" >10.1016/j.jpba.2025.116831</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria

  • Original language description

    Monitoring patients with phenylketonuria (PKU) requires accurately measuring phenylalanine and tyrosine levels in a small volume of blood samples obtained by the dried blood spot (DBS) technique. The aim was to study selected parameters influencing the quantitative results. Phenylalanine and tyrosine were extracted from DBS samples with methanol, and 5 internal standard introduction techniques were tested. Phenylalanine and tyrosine levels were measured in 6-mm discs punched from DBS, pre-punched 9-mm discs containing the entire DBS sample, and liquid blood by HPLC-MS-MS. Levels in 6-mm discs punched from DBS measured by HPLC-MS/MS were compared with those measured by the HPLC-FLD. The analytical parameters of the method are satisfactory, linearity in the range of 25–1200 μmol/L (LOD, LOQ and LLOQ values 0.2 μmol/L, 0.5 μmol/L and 3.8 μmol/L for phenylalanine, 0.5 μmol/L, 1.5 μmol/L and 5.1 μmol/L for tyrosine), within-run precision 1.8 %–3.7 % for phenylalanine, 1.9 %–2.7 % for tyrosine, between-run precision 4.7 %–5.9 % for phenylalanine, 4.1 %–5.4 % for tyrosine, recovery 93.8 %–100.4 % for phenylalanine and 93.7 %–99.1 % for tyrosine. Good agreement was found between phenylalanine and tyrosine concentrations in 6-mm discs punched from DBS (R = 0.896, p &lt; 0.001, and R = 0.907, p &lt; 0.001, respectively), pre-punched 9-mm discs containing the entire DBS sample (R = 0.960, p &lt; 0.001, and R = 0.950, p &lt; 0.001, respectively) and liquid blood, as well as between phenylalanine and tyrosine concentrations obtained by HPLC-MS/MS and HPLC-FLD (R = 0.968, p &lt; 0.001, and R = 0.984, p &lt; 0.001, respectively). The presented method is suitable for monitoring patients with PKU.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Pharmaceutical and Biomedical Analysis

  • ISSN

    0731-7085

  • e-ISSN

    1873-264X

  • Volume of the periodical

    260

  • Issue of the periodical within the volume

    August 2025

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    116831

  • UT code for WoS article

    001454117200001

  • EID of the result in the Scopus database

    2-s2.0-105000487145