Tribotechnical diagnostics as a tool for determining of a change interval of a motor oil
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25510%2F16%3A39902134" target="_blank" >RIV/00216275:25510/16:39902134 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Tribotechnical diagnostics as a tool for determining of a change interval of a motor oil
Original language description
The article presents result of testing of two types of used motor oils with the same specification ACEA E4/E7, SAE 10W-40 by methods tribotechnical diagnostics, from two different suppliers. Evaluation of selected tribodiagnostics parameters did not prove that the exchange interval prolongation of more expensive motor oil would ensure all required functions as it had been declared by the supplier's sales representative.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JS - Reliability and quality management, industrial testing
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Deterioration, Dependability, Diagnostics 2016
ISBN
978-80-7231-376-1
ISSN
—
e-ISSN
—
Number of pages
9
Pages from-to
213-221
Publisher name
Univerzita obrany v Brně
Place of publication
Brno
Event location
Brno
Event date
Oct 11, 2016
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—