Odezva vysokých štíhlých konstrukcí na zatížení větrem

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F07%3APU72148" target="_blank" >RIV/00216305:26110/07:PU72148 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Odezva vysokých štíhlých konstrukcí na zatížení větrem

  • Original language description

    Tall, slender and flexible structures are dominantly loaded by airlow. their dynamic response is more pronounced than that of other types of structures, as their natural frequencies are significantly lower, in the domain of high values of the wind energy. The paper presents methods of determining the dynamic load of the wind and dynamic effects of wind on the structure of an anchored mast. The wind load is analysed according to the Eurocode 1: Action on structures - Part 1-4. General actions - Wind actions, which defines the general requirements concerning the wind load on a structure with respect to the Euroocde 3: Design of steel structures - Part 3-1: Towers, mast and chimneys - Towers and masts.

  • Czech name

    Odezva vysokých štíhlých konstrukcí na zatížení větrem

  • Czech description

    Tall, slender and flexible structures are dominantly loaded by airlow. their dynamic response is more pronounced than that of other types of structures, as their natural frequencies are significantly lower, in the domain of high values of the wind energy. The paper presents methods of determining the dynamic load of the wind and dynamic effects of wind on the structure of an anchored mast. The wind load is analysed according to the Eurocode 1: Action on structures - Part 1-4. General actions - Wind actions, which defines the general requirements concerning the wind load on a structure with respect to the Euroocde 3: Design of steel structures - Part 3-1: Towers, mast and chimneys - Towers and masts.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JM - Structural engineering

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/1M0579" target="_blank" >1M0579: Centre for Integrated Design of Advanced Structures</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2007

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    New trends in statics and dynamics in buildings

  • ISBN

    978-80-227-2732-7

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    121-124

  • Publisher name

    Neuveden

  • Place of publication

    Bratislava, Slovenská republika

  • Event location

    Bratislava

  • Event date

    Oct 18, 2007

  • Type of event by nationality

    EUR - Evropská akce