Evaluation of the Concrete Structure Integrity after Temperature Degradation via Nonlinear Ultrasonic Measurements
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F12%3APU101200" target="_blank" >RIV/00216305:26110/12:PU101200 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Evaluation of the Concrete Structure Integrity after Temperature Degradation via Nonlinear Ultrasonic Measurements
Original language description
The paper deals with nonlinear interaction between elastic wave and structural defects in concrete specimens. Our objective consisted of determining how the freeze-thaw cycle application induced degradation that depends on the input structure initial quality.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JN - Civil engineering
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP104%2F10%2F1430" target="_blank" >GAP104/10/1430: Damage Monitoring of Building Structure Components by Nonlinear Ultrasonic Spectroscopy</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Defektoskopie 2012 / NDE for Safety
ISBN
978-80-214-4609-0
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
139-142