All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU112557" target="_blank" >RIV/00216305:26110/14:PU112557 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of Initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures Usage of initial surface absorption method for evaluation of degradation of concrete exposed to high temperatures

  • Original language description

    The high temperatures have negative influence on concrete constructions in term of failure of inner concrete structure. The rate of permeability of surface layer is significant for escape velocity of water vapour from interior volume of the concrete. Theexplosive spalling could occur if the rate of permeability of surface layer is low. In case of reinforced concrete the bonded coating of armature could be destroyed and armature is no more protected and loses its strength. The Initial Surface AbsorptionTest (ISAT) is one of methods how to determine the surface water permeability of concrete and other building materials. The study deals with changes of water permeability of concrete exposed to high temperatures. Concrete mixtures with basalt aggregatesand expanded clay aggregates were examined.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    JN - Civil engineering

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GAP104%2F12%2F1988" target="_blank" >GAP104/12/1988: Study of interactions of components of cementitious composites exposed to high temperatures</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů