The bond strength by pull-off and direct tensile strength of concrete damaged by elevated temperatures

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU128471" target="_blank" >RIV/00216305:26110/18:PU128471 - isvavai.cz</a>

  • Result on the web

    <a href="http://iopscience.iop.org/article/10.1088/1757-899X/385/1/012047" target="_blank" >http://iopscience.iop.org/article/10.1088/1757-899X/385/1/012047</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1757-899X/385/1/012047" target="_blank" >10.1088/1757-899X/385/1/012047</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The bond strength by pull-off and direct tensile strength of concrete damaged by elevated temperatures

  • Original language description

    This paper presents the results of an experimental study of selected characteristics of concrete following its exposure to high temperatures. The monitored parameter was the influence of high temperatures on the bond strength and tensile strength of concrete. The bond strength was tested by a pull-off test, the tensile strength was determined as the direct tensile strength. Experimental concrete panels of 2300 x 1300 x 150 mm were exposed to high temperatures (corresponding to the temperatures in a normal fire) using a fire test furnace at the AdMaS Science Centre of the Faculty of Civil Engineering, Brno University of Technology. The direct tensile strength test was performed on cylinders (diameter of 100 mm and length of 100 mm) made from core samples taken from the panel. The pull-off test was performed on the surface exposed to high temperatures. The results of the experiment show a significant influence of high temperatures on the examined characteristics, and both characteristics were found to significantly decrease with a growing thermal load.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Construmat 2018

  • ISBN

  • ISSN

    1757-8981

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    1-6

  • Publisher name

    IOP Publishing

  • Place of publication

    Bristol

  • Event location

    Herľany

  • Event date

    Jun 13, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article