Transient simulation study of floor heating systems

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU129208" target="_blank" >RIV/00216305:26110/18:PU129208 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1556/1848.2019.0006" target="_blank" >http://dx.doi.org/10.1556/1848.2019.0006</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1556/1848.2019.0006" target="_blank" >10.1556/1848.2019.0006</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Transient simulation study of floor heating systems

  • Original language description

    This case study is aimed at transient simulation of floor heating systems. There is comparison of surface floor temperatures and heat fluxes changes of different systems over time. The first studied system is a dry floor heating system which consists of system boards made from insulation material, spreader plates, and it is covered by cement fiber boards. The second examined system is heavy wet concrete floor heating system whose heating power is set identically as heating power of dry floor heating system. Mean temperature of heating water is investigated. All simulations, both time steady-state and transient, are performed in software CalA. Reduction of duration and computational performance of simulation is achieved by creation of a surrogate model. The surrogate model evinces identical surface temperatures and heat fluxes. Total number of computational grid is reduced and therefore lower number of equations is solved. Results show that dry floor heating system has faster response than concreate floor heating system. It is caused by lower weight and lower thermal capacity of this system.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

    <a href="/en/project/LO1408" target="_blank" >LO1408: AdMaS UP – Advanced Building Materials, Structures and Technologies</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Review of Applied Sciences and Engineering

  • ISSN

    2063-4269

  • e-ISSN

  • Volume of the periodical

    9

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    HU - HUNGARY

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85068924277