Strengthening of Arched Masonry Structures by Additional Reinforcement: Design Approaches and Comparison to Experiments
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU131017" target="_blank" >RIV/00216305:26110/18:PU131017 - isvavai.cz</a>
Result on the web
<a href="https://bjrbe-journals.rtu.lv/issue/view/122" target="_blank" >https://bjrbe-journals.rtu.lv/issue/view/122</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.7250/bjrbe.2018-13.419" target="_blank" >10.7250/bjrbe.2018-13.419</a>
Alternative languages
Result language
angličtina
Original language name
Strengthening of Arched Masonry Structures by Additional Reinforcement: Design Approaches and Comparison to Experiments
Original language description
The main aim of this article is to present design approaches for calculating the additional strengthening of masonry arches with the use of the strut-and-tie method and applicable standards and their comparison with the experiments that have demonstrated the functionality of the described method. Presented method is one of the methods of maintaining historical vaulted masonry structures is additional strengthening by non-prestressed reinforcement from the face of the vault, a method that is also used to improve the behaviour of new masonry structures. This method of strengthening has its advantages, especially in the minimization of alterations to the structure and its simplicity of application. In order to verify the behaviour of masonry arches strengthened by additional reinforcement, experiments have been performed in recent years on additionally strengthened vaults with metallic helical reinforcement and non-metallic composite glass reinforcement (GFRP). These experiments have demonstrated the significant influence of additional reinforcement on the carrying capacity of masonry vaults. The growth of bearing capacity was more than eight-fold. From a comparison of design approaches with experiments is evident that approaches to the design of additionally strengthened masonry based on valid standards are possible. The comparison of results moreover demonstrates the possibility of using approaches based on the strut-and-tie method.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20102 - Construction engineering, Municipal and structural engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Baltic Journal of Road and Bridge Engineering
ISSN
1822-427X
e-ISSN
1822-4288
Volume of the periodical
13
Issue of the periodical within the volume
3
Country of publishing house
LT - LITHUANIA
Number of pages
178
Pages from-to
313-330
UT code for WoS article
000451094800009
EID of the result in the Scopus database
2-s2.0-85055648746