The Issue of the Daylighting Intensity by Light Guides
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU131033" target="_blank" >RIV/00216305:26110/19:PU131033 - isvavai.cz</a>
Result on the web
<a href="https://iopscience-iop-org.ezproxy.lib.vutbr.cz/article/10.1088/1757-899X/471/6/062025" target="_blank" >https://iopscience-iop-org.ezproxy.lib.vutbr.cz/article/10.1088/1757-899X/471/6/062025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/471/6/062025" target="_blank" >10.1088/1757-899X/471/6/062025</a>
Alternative languages
Result language
angličtina
Original language name
The Issue of the Daylighting Intensity by Light Guides
Original language description
The issue of the efficiency of use and determination of the operational efficiency of the designed light sources is relevant during the process of lighting design. The contribution deals with the illumination of the interior by the tubular light guides during design and operation itself. The measurement of the luminance, the illumination of the exterior and the interior was carried out on experimental wooden building in Brno belonging to VUT FAST (Czech Republic). In one case, the brightness of the sky was also measured. The assessed tubular light guides Sunizer with the length of tube 2 m and with the diameter of 320 mm passes through the roof structure and through the ceiling structure into the interior corridor of the wooden building. Prior to the start of the measurement, the measuring sensors were placed in the center of the diffusers of the two measured tubular light guides at the floor level. Another one sensor was placed at the midpoint between the diffusers at the floor level. Subsequently, another sensor was placed on the roof of the building in the exterior. The sensor is placed next to the dome of the light guide so that it is not overshadowed. The sensors were connected to the datalogger and the 5-minute measurement was performed at all four locations simultaneously at time intervals after one minute. The values of the sky brightness always in four directions were determined were determined before the measurement, in the middle of the measurement and at the end of the measurement. The sky type was determined visually for some of the measurements. Finally, the measured data from the luxmeter was stored and the ratios of illumination of the interior and exterior were calculated. Subsequently, the measured data are compared with the simulations obtained from the software Holigilm and Velux Daylight Visualizer. The benchmark is the ratio between indoor and outdoor illumination, the so-called daylight factor. Finally, there is an evaluation, a graph showing
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
60402 - Architectural design
Result continuities
Project
<a href="/en/project/LO1408" target="_blank" >LO1408: AdMaS UP – Advanced Building Materials, Structures and Technologies</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Number of pages
11
Pages from-to
1-11
Publisher name
IOP PUBLISHING LTD
Place of publication
BRISTOL
Event location
Praha
Event date
Jun 18, 2018
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000465811802076