All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Assessment of Construction Details in Terms of 3D Thermal Fields and the Impact on Building Design

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU136293" target="_blank" >RIV/00216305:26110/19:PU136293 - isvavai.cz</a>

  • Result on the web

    <a href="https://iopscience.iop.org/article/10.1088/1755-1315/290/1/012097/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1755-1315/290/1/012097/pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1755-1315/290/1/012097" target="_blank" >10.1088/1755-1315/290/1/012097</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Assessment of Construction Details in Terms of 3D Thermal Fields and the Impact on Building Design

  • Original language description

    Thermal bridge is a very common and undesirable phenomenon in a building. Thermal joint (bridge) is usually based on material or geometry reasons or their combinations. Many types (connection of window – wall, pillar – wall), can be calculated and evaluated sufficiently in 2D section, but in some types it is necessary to take into account 3D heat conduction. For example: a corner with ceiling (roof) and two walls where is strong deformation of isotherms and the internal surface temperature is definitely lower than in 2D section. According to the Czech Technical Standard it is necessary to fulfil law requirement – Temperature Factor at internal surface lowest temperature "at each location". Recommendation is solving of "differential equation multi-dimensional of thermal field". In this case of "building corner" project engineer has to decide for 3D modelling. In the contribution there is presented a mistake in 2D model, the situation when it is necessary to use 3D model. Additionally, there are recommendations to eliminate the risk of condensation and mould.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20103 - Architecture engineering

Result continuities

  • Project

    <a href="/en/project/2A-3TP1%2F090" target="_blank" >2A-3TP1/090: Special composite materials with high ability of accumulation of infra-red emission.</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Central Europe towards Sustainable Building (CESB19), IOP Conference Series: Earth and Environmental Science

  • ISBN

    9781510890770

  • ISSN

    1755-1307

  • e-ISSN

  • Number of pages

    7

  • Pages from-to

    124-133

  • Publisher name

    IOP Publishing Ltd

  • Place of publication

    Praha

  • Event location

    Praha

  • Event date

    Jul 2, 2019

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article