All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Hygrothermal interaction in Romanesque rotunda in Znojmo

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F20%3APU138504" target="_blank" >RIV/00216305:26110/20:PU138504 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.scopus.com/inward/record.url?eid=2-s2.0-85099130306&partnerID=MN8TOARS" target="_blank" >http://www.scopus.com/inward/record.url?eid=2-s2.0-85099130306&partnerID=MN8TOARS</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Hygrothermal interaction in Romanesque rotunda in Znojmo

  • Original language description

    The contribution is aimed at the hygrothermal interaction of an indoor climate with an original mural painting in the Romanesque Rotunda in Znojmo. This hygrothermal interaction has been analysed through impact of the heating, ventilation, and number of visitors on the indoor climate with the subsequent impact on the mural painting. This triple parametrical numerical simulation was performed in the WUFI®Plus 3.0 software and independently in the BSim 2000 software and CalA 4.0 software. The numerical simulation of the indoor climate is validated with real long-term measurements from 2011 – 2015 in hourly time steps. A correlation of 99 % was obtained for the WUFI®Plus 3.0 software with the BSim 2000 software for the indoor climate and a correlation of 97 % was obtained for the hygrothermal diffusion in the peripheral wall with the CalA 4.0 software. The obtained results show that a thermal stress up to 2.6 K and a dryness effect up to 18.3 kg/m3 caused by the intensive heating act on the mural painting. A thermal stress up to 1.4 K and a dryness effect up to 26.8 kg/m3 was also obtained by the intensive ventilation on the mural painting. This obtained knowledge shows that a natural indoor climate in combination with conservation heating should be preferred over a controlled indoor climate in the Romanesque Rotunda in Znojmo.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20103 - Architecture engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Simulace budov a techniky prostředí 2020. Sborník 11. konference IBPSA-CZ

  • ISBN

    978-80-907423-1-4

  • ISSN

    1210-1389

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    316-321

  • Publisher name

    Society of Environmental Engineering

  • Place of publication

    Praha

  • Event location

    Brno

  • Event date

    Nov 5, 2020

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article