Medium-Scale Fire Resistance Testing of Timber Structures with Composite Cement Fibre Materials

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F23%3APU150374" target="_blank" >RIV/00216305:26110/23:PU150374 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/buildings13020527" target="_blank" >https://doi.org/10.3390/buildings13020527</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/buildings13020527" target="_blank" >10.3390/buildings13020527</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Medium-Scale Fire Resistance Testing of Timber Structures with Composite Cement Fibre Materials

  • Original language description

    The combustibility of natural wood presents a negative impact for using this material in buildings. Timber elements can be cladded with boards made of non-combustible materials. This study represents a group of options for increasing the resistance of timber against the effects of fire and the possibility of slowing down the effect of thermal degradation of wood. The aim of this study is focused on an experimental testing of structures with timber elements protected by cement fibre boards as a non-combustible fire retardant. Cement fibre boards are fibre-reinforced composite materials used for systems of dry constructions. These boards present the highest degree of fire reaction class (A1). The behaviour of the structure, loaded by the effects of fire, was monitored during the experiment. The specimen was tested with reduced dimensions. The temperature loading corresponded to the procedure according to the standards. The final fire resistant (FR) results were evaluated in accordance with the requirements for the selected limit states of FR. This was assessed based on the measured temperatures and the whole condition of the tested specimen. The specimen fulfilled the fire-separating function of the structure for the classification times.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Buildings

  • ISSN

    2075-5309

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    12

  • Pages from-to

    1-12

  • UT code for WoS article

    000938934700001

  • EID of the result in the Scopus database

    2-s2.0-85149225907