Spectral test method for light transmittance of transparent building components using different artificial radiation sources
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F23%3APU150846" target="_blank" >RIV/00216305:26110/23:PU150846 - isvavai.cz</a>
Alternative codes found
RIV/62156489:43410/23:43924642
Result on the web
<a href="https://aipp.silverchair-cdn.com/aipp/content_public/journal/acp/2801/1/10.1063_5.0146815/1/030004_1_5.0146815.pdf?Expires=1710918564&Signature=MIL9waL7qU1WGwix8~mxtMuyXCy5Ezx4pZqY6hm39HDwoXCbJ~vFiTQ2RSePBcDmx4Q-3k-yo~VOmaAsP4U1KZqXkDBfxUttL4bA7yb9EqYLHK" target="_blank" >https://aipp.silverchair-cdn.com/aipp/content_public/journal/acp/2801/1/10.1063_5.0146815/1/030004_1_5.0146815.pdf?Expires=1710918564&Signature=MIL9waL7qU1WGwix8~mxtMuyXCy5Ezx4pZqY6hm39HDwoXCbJ~vFiTQ2RSePBcDmx4Q-3k-yo~VOmaAsP4U1KZqXkDBfxUttL4bA7yb9EqYLHK</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0146815" target="_blank" >10.1063/5.0146815</a>
Alternative languages
Result language
angličtina
Original language name
Spectral test method for light transmittance of transparent building components using different artificial radiation sources
Original language description
Intention of this study concerns the investigation of the spectral test method for its potential implementation in analyzing thermo-optical changes in a phase change material based on building components. As solar simulators are considered to be the key methodologies for conducting solar-based research under a well-controlled environment, this study presents a simple design of a low and high flux solar simulator to provide optical testing of specific glass components. The optical system was designed as a lamp of one unit and a parabolic reflector used to irradiate test samples implemented in a squared box with an optical detector. Second, the experimental setup was equipped with a spectrophotometer, and the validity of transmittance data obtained with a reference building’s transparent systems, like a simple glass pane and Plexiglas, was tested by measurements comparison with results obtained using a UV/VIS/NIR spectrophotometer in the light transmittance spectra. The results of the experiment revealed light transmittance data obtained from spectrophotometers and compared with reference simple glass systems.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
<a href="/en/project/GA20-00630S" target="_blank" >GA20-00630S: Climate responsive components integrated in energy and environmentally efficient building envelope</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Central European Symposium on Thermophysics 2022 (CEST 2022)
ISBN
978-0-7354-4722-6
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
„030004-1“-„030004-6“
Publisher name
AIP Publishing
Place of publication
Melville
Event location
Olomouc
Event date
Aug 31, 2022
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—