Stress Analysis of the Hip Joint Endoprosthesis Ceramics Head with Different Shapes of the Cone Opening
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F08%3APU79938" target="_blank" >RIV/00216305:26210/08:PU79938 - isvavai.cz</a>
Alternative codes found
RIV/61388998:_____/08:00322481
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Stress Analysis of the Hip Joint Endoprosthesis Ceramics Head with Different Shapes of the Cone Opening
Original language description
During the analysis of the fracture surfaces of the destructed hip joint endoprosthesis ceramics heads it was detected that the shape (size and the position) of the cone end in the bottom of the cone opening were very different. The paper presents the influence of five typical shapes of the cone end on the stress in the ceramic head. The computational modelling is realized for two outer diameters of the ceramic head - 28 mm and 32 mm and three depths of it's cone. The system FEM - ANSYS was used for computational modelling of the stress and deformation of analyzed system (testing stem and ceramic head). Loading of the analyzed system is according to norm ISO 7206-5. There are assumed shape deviations of the cone surfaces - interaction of the ovality and different degree of taper of the stem and the head cone.
Czech name
Napjatostní analýza keramické hlavice totální kyčelní endoprotézy s různým tvarem jejího dna
Czech description
During the analysis of the fracture surfaces of the destructed hip joint endoprosthesis ceramics heads it was detected that the shape (size and the position) of the cone end in the bottom of the cone opening were very different. The paper presents the influence of five typical shapes of the cone end on the stress in the ceramic head. The computational modelling is realized for two outer diameters of the ceramic head - 28 mm and 32 mm and three depths of it's cone. The system FEM - ANSYS was used for computational modelling of the stress and deformation of analyzed system (testing stem and ceramic head). Loading of the analyzed system is according to norm ISO 7206-5. There are assumed shape deviations of the cone surfaces - interaction of the ovality and different degree of taper of the stem and the head cone.
Classification
Type
D - Article in proceedings
CEP classification
BO - Biophysics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
13th International Conference on Biomedical Engineering
ISBN
978-3-540-92840-9
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
—
Publisher name
Springer
Place of publication
Singapore
Event location
Singapore
Event date
Dec 3, 2008
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—