All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Impact of air distribution system on quality of ventilation in small aircraft cabin

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU104743" target="_blank" >RIV/00216305:26210/13:PU104743 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0360132313002333" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0360132313002333</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.buildenv.2013.08.007" target="_blank" >10.1016/j.buildenv.2013.08.007</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Impact of air distribution system on quality of ventilation in small aircraft cabin

  • Original language description

    A ventilation system of sufficient performance is the basic condition for comfort and health risk free environment in enclosed aircraft cabin spaces. The airflow pattern and spreading of fresh air into the cabin space mainly depend on the type of the airdistribution system and location of heat sources/sinks. The present study deals with the investigation of the dependency between the type of the air distribution system and indoor air quality in a cabin of a small transport aircraft. The mock-up interior geometry of a small aircraft cabin for nine passengers was adopted for the investigation. Three types of the air distribution system were investigated: a typical mixing ventilation system, a modified mixing ventilation system and an under-aisle displacement ventilation system. The quality of ventilation was assessed based on the local mean age of air using CFD software Star-CCM+. At first, the CFD model of a typical mixing ventilation was validated against the experimental data of airf

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BJ - Thermodynamics

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    BUILDING AND ENVIRONMENT

  • ISSN

    0360-1323

  • e-ISSN

  • Volume of the periodical

    2013

  • Issue of the periodical within the volume

    69

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    12

  • Pages from-to

    171-182

  • UT code for WoS article

    000326429000017

  • EID of the result in the Scopus database