All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Experimental investigation of stabilization of flowing water temperature with a water-PCM heat exchanger

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU110264" target="_blank" >RIV/00216305:26210/14:PU110264 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1051/epjconf/20146702046" target="_blank" >http://dx.doi.org/10.1051/epjconf/20146702046</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1051/epjconf/20146702046" target="_blank" >10.1051/epjconf/20146702046</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Experimental investigation of stabilization of flowing water temperature with a water-PCM heat exchanger

  • Original language description

    Experiments have been carried out in order to investigate the stabilization of water temperature with a water-PCM heat exchanger. The water-PCM heat exchanger was of a rather simple design. It was a round tube, through which the water flowed, surrounded with an annular layer of PCM. The heat exchanger was divided into one meter long segments (modules) and the water temperature was monitored at the outlet of each of the segments. A paraffin-based PCM with the melting temperature of 42 C was used in the experiments. The experimental set-up consisted of two water reservoirs kept at different temperatures, the water-PCM heat exchanger, PC controlled valves and a data acquisition system. As the first step a response to a step change in the water temperature at the inlet of the heat exchanger was investigated. Subsequently, a series of experiments with a square wave change of temperature at the inlet of the exchanger were carried out. The square wave temperature profile was achieved by periodic switching between the two water reservoirs. Several amplitudes and periods of temperature square wave were used. The results of experiments show that a water-PCM heat exchanger can effectively be used to stabilize the flowing water temperature when the inlet temperature changes are around the melting range of the PCM.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    EPJ Web of Conferences

  • ISBN

    978-80-260-5375-0

  • ISSN

    2100-014X

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    "02046-p.1"-"02046-p.4"

  • Publisher name

    Neuveden

  • Place of publication

    Neuveden

  • Event location

    Kutná Hora

  • Event date

    Nov 19, 2013

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000343672100049