The flue gas desulphurization at the first stage of the absorber - O-element
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F17%3APU120614" target="_blank" >RIV/00216305:26210/17:PU120614 - isvavai.cz</a>
Result on the web
<a href="http://www.aidic.it/cet/17/56/319.pdf" target="_blank" >http://www.aidic.it/cet/17/56/319.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET1756319" target="_blank" >10.3303/CET1756319</a>
Alternative languages
Result language
angličtina
Original language name
The flue gas desulphurization at the first stage of the absorber - O-element
Original language description
Pilot plant wet scrubber is comprised of first stage and second stage. In our experimental setup, O-element is used as a first stage. O-element replaces venturi scrubber that is currently used in practice. O-element is a device used to homogenize the gas-liquid mixture. Upon contact of flue gas and liquid, the hot flue gas is cooled and pollutants are being removed from flue gas. As a second stage a packed column with the structured packing is designed. By a gradual transition from the planar embodiment of the O-element (the O-element 2R) to the spatial arrangement, the four branched O-element - the O-element 4R originated. The design of equipment for the larger flue gas flow rate is necessary, because the waste to energy plants incinerating the municipal and hazardous waste commonly produce flue gas with flowrates in the tens of thousands m3/h. For such flue gas flow rate would the originally designed device O-element 2R be too space-demanding. Spraying a liquid in the four-branched-O element can be performed in two ways. Firstly, it could be managed in the same manner as in two-branched O-element, i.e. through the orifices in the bottom arcs of the equipment, or by spraying of the liquid around the circumference of the inlet pipe. Experiments were performed with the two O-4R elements with liquid spray positioned around the perimeter of the inlet pipe and with the liquid spray through the nozzles in the lower arcs of the equipment. The main observed parameter was the SO2 removal efficiency depending on the L/G ratio. In addition even more important indicator as SO2 removal efficiency was monitored and it was an O-element pressure loss.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20402 - Chemical process engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Chemical Engineering Transactions
ISSN
2283-9216
e-ISSN
—
Volume of the periodical
2017
Issue of the periodical within the volume
56
Country of publishing house
IT - ITALY
Number of pages
6
Pages from-to
1909-1914
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85019417023