All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Robustness and Accuracy of the Particle Swarm Optimisation Method in the Solution of Inverse Heat Transfer Problems with Phase Change

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F21%3APU142273" target="_blank" >RIV/00216305:26210/21:PU142273 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.cetjournal.it/cet/21/88/050.pdf" target="_blank" >https://www.cetjournal.it/cet/21/88/050.pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3303/CET2188050" target="_blank" >10.3303/CET2188050</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Robustness and Accuracy of the Particle Swarm Optimisation Method in the Solution of Inverse Heat Transfer Problems with Phase Change

  • Original language description

    Some engineering heat transfer problems cannot be solved directly as certain parameters influencing heat transfer are unknown. This is where the solution of inverse heat transfer problems might be utilized. The paper explores application of the Particle Swarm Optimisation (PSO) method to heat transfer problems with phase change. In order to assess the robustness and accuracy of the method, the study was conducted on simulation results. The explored case is an air-PCM heat exchanger. In the first step, the simulations with various values of parameters influencing heat transfer were performed. All cases were simulated as transient with time-dependent boundary conditions. In the second step, some of these parameters (phase change temperature, density, thermal conductivity, etc.) were assumed to be unknown and they were obtained from the simulation results with the use of the PSO method. The cost function was defined in the form of a root mean square error between the simulation results (the outlet air temperature from the heat exchanger) and the results of the optimized scenario. The number of unknown parameters varied from one to seven (in case of the description of the relationship of effective heat capacity on temperature, which was parameterized in the form of an asymmetric Gaussian function). The results have shown that the PSO is a robust and accurate tool with only up to 2 % difference in the enthalpy of fusion and no significant discrepancies during the higher dimension optimisation.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20303 - Thermodynamics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Chemical Engineering Transactions

  • ISSN

    2283-9216

  • e-ISSN

  • Volume of the periodical

    88

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    IT - ITALY

  • Number of pages

    6

  • Pages from-to

    301-306

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85122566815