Robustness and Accuracy of the Particle Swarm Optimisation Method in the Solution of Inverse Heat Transfer Problems with Phase Change
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F21%3APU142273" target="_blank" >RIV/00216305:26210/21:PU142273 - isvavai.cz</a>
Result on the web
<a href="https://www.cetjournal.it/cet/21/88/050.pdf" target="_blank" >https://www.cetjournal.it/cet/21/88/050.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET2188050" target="_blank" >10.3303/CET2188050</a>
Alternative languages
Result language
angličtina
Original language name
Robustness and Accuracy of the Particle Swarm Optimisation Method in the Solution of Inverse Heat Transfer Problems with Phase Change
Original language description
Some engineering heat transfer problems cannot be solved directly as certain parameters influencing heat transfer are unknown. This is where the solution of inverse heat transfer problems might be utilized. The paper explores application of the Particle Swarm Optimisation (PSO) method to heat transfer problems with phase change. In order to assess the robustness and accuracy of the method, the study was conducted on simulation results. The explored case is an air-PCM heat exchanger. In the first step, the simulations with various values of parameters influencing heat transfer were performed. All cases were simulated as transient with time-dependent boundary conditions. In the second step, some of these parameters (phase change temperature, density, thermal conductivity, etc.) were assumed to be unknown and they were obtained from the simulation results with the use of the PSO method. The cost function was defined in the form of a root mean square error between the simulation results (the outlet air temperature from the heat exchanger) and the results of the optimized scenario. The number of unknown parameters varied from one to seven (in case of the description of the relationship of effective heat capacity on temperature, which was parameterized in the form of an asymmetric Gaussian function). The results have shown that the PSO is a robust and accurate tool with only up to 2 % difference in the enthalpy of fusion and no significant discrepancies during the higher dimension optimisation.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20303 - Thermodynamics
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Chemical Engineering Transactions
ISSN
2283-9216
e-ISSN
—
Volume of the periodical
88
Issue of the periodical within the volume
1
Country of publishing house
IT - ITALY
Number of pages
6
Pages from-to
301-306
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85122566815