Treatment of Hospital wastewater with submerged aerobic fixed film reactor coupled with tube-settler
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU141552" target="_blank" >RIV/00216305:26210/22:PU141552 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0045653521023109?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0045653521023109?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2021.131838" target="_blank" >10.1016/j.chemosphere.2021.131838</a>
Alternative languages
Result language
angličtina
Original language name
Treatment of Hospital wastewater with submerged aerobic fixed film reactor coupled with tube-settler
Original language description
In this study, Hospital wastewater was treated using a submerged aerobic fixed film (SAFF) reactor coupled with tubesettler in series. SAFF consisted of a column with an up-flow biofilter. The biological oxygen demand (BOD)5, chemical oxygen demand (COD), nitrate and phosphate were the chosen pollutants for evaluation. The pollutants removal efficiency was determined at varying organic loading rates and hydraulic retention time. The organic loading rate was varied between 0.25 and 1.25 kg COD m−3 d−1. The removal efficiency of SAFF and tubesettler combined was 75 % COD, 67 % BOD and 67 % phosphate, respectively. However, nitrate saw an increase in concentration by 25 %. SAFF contribution in the removal of COD, BOD5 and Phosphate was 48 %, 46 % and 29 %, respectively. While for accumulation of nitrate, it was responsible for 56%, respectively. Tubesettler performed better than SAFF with 52 %, 54 % and 69 % reduction of COD, BOD5 and phosphate, respectively. But in terms of nitrate, tubesettler was responsible for 44 % accumulation. The nutrient reduction decreased with an increase in the organic loading rate. Nitrification was observed in the SAFF and tubesettler, which indicated a well-aerated system. An anaerobic unit is required for completing the denitrification process and removing nitrogen from the effluent. The better performance of tubesettler over SAFF calls for necessitates extended retention time over design criteria. Further studies are beneficial to investigate the impact of pharmaceutical compounds on the efficiency of SAFF.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20704 - Energy and fuels
Result continuities
Project
<a href="/en/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Sustainable Process Integration Laboratory (SPIL)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
CHEMOSPHERE
ISSN
0045-6535
e-ISSN
1879-1298
Volume of the periodical
neuveden
Issue of the periodical within the volume
286
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
131838-131838
UT code for WoS article
000704764300003
EID of the result in the Scopus database
2-s2.0-85112351838