All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Correlation of characteristic signals of laser-induced plasmas

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU145033" target="_blank" >RIV/00216305:26210/22:PU145033 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0584854722001203" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0584854722001203</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.sab.2022.106476" target="_blank" >10.1016/j.sab.2022.106476</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Correlation of characteristic signals of laser-induced plasmas

  • Original language description

    Complementary methods are introduced to laser-induced breakdown spectroscopy measurement systems in order to provide complete information about the investigated sample, phenomena beyond laser-matter interaction and evolution of laser-induced plasmas and its properties. Another use of such complementary signals is in their potential use for signal standardization. So far one additional method is used at a time to achieve this goal, be it direct imaging of the plasma, shadowgraphy method, measurement of the sound signal or energy of the laser pulse. In this work we were able to record all above mentioned data at the same time as the LIBS spectra or even energy of the individual laser pulses. This allowed us to observe correlation between all the data with optical emission signal of laser induced plasmas. Each data pair is represented by correlation coefficient, where the average value of correlation coefficients R2 is 0.87. After correcting the data with the energy of laser pulse and optical emission signal, we achieved average value of the correlation coefficients R2 0.98.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)

Result continuities

  • Project

    <a href="/en/project/EF19_073%2F0016948" target="_blank" >EF19_073/0016948: Quality internal grants at BUT</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY

  • ISSN

    1873-3565

  • e-ISSN

  • Volume of the periodical

    194

  • Issue of the periodical within the volume

    106476

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    1-6

  • UT code for WoS article

    000826530500002

  • EID of the result in the Scopus database

    2-s2.0-85132926767