All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Experimental Investigation of Microcontroller-Based Acoustic Temperature Transducer Systems

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F23%3APU146933" target="_blank" >RIV/00216305:26210/23:PU146933 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.mdpi.com/1424-8220/23/2/884" target="_blank" >https://www.mdpi.com/1424-8220/23/2/884</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/s23020884" target="_blank" >10.3390/s23020884</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Experimental Investigation of Microcontroller-Based Acoustic Temperature Transducer Systems

  • Original language description

    Temperature transducers are commonly used to monitor process parameters that are controlled by various types of industrial controllers. The purpose of this study is to design and model a simple microcontroller-based acoustic temperature transducer based on the variations of resonance conditions in a cylindrical resonance tube. The transducer’s operation is based on the generation of an acoustic standing wave in the free resonance mode of generation within a cylindrical resonance tube which is converted into a train of pulses using Schmitt trigger circuit. The frequency of the generated standing wave (i.e., the train of pulses) is measured by the Arduino Uno microcontroller, where a digital pin is used to acquire pulses that are counted using a build-in software function in an Arduino IDE environment. Experimental results are performed for three sizes of diameters to investigate the effect of the diameter of resonance tube on the obtained results. The maximum nonlinearity error according to Full-Scale Deflection (FSD) is about 2.3 percent, and the relative error of the transducer is evaluated using experimental findings and the regression model. The circuit simplicity and design of the suggested transducer, as well as the linearity of its measurements, are notable.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20302 - Applied mechanics

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    SENSORS

  • ISSN

    1424-8220

  • e-ISSN

    1424-3210

  • Volume of the periodical

    23

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    15

  • Pages from-to

    1-15

  • UT code for WoS article

    000927765600001

  • EID of the result in the Scopus database

    2-s2.0-85146490240