A Case Study on Assessing the Capability and Applicability of an Articulated Arm Coordinate Measuring Machine and a Touch-Trigger Probe for On-Machine Measurement
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F24%3APU152711" target="_blank" >RIV/00216305:26210/24:PU152711 - isvavai.cz</a>
Result on the web
<a href="https://www.mdpi.com/2075-1702/12/12/841" target="_blank" >https://www.mdpi.com/2075-1702/12/12/841</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/machines12120841" target="_blank" >10.3390/machines12120841</a>
Alternative languages
Result language
angličtina
Original language name
A Case Study on Assessing the Capability and Applicability of an Articulated Arm Coordinate Measuring Machine and a Touch-Trigger Probe for On-Machine Measurement
Original language description
In modern manufacturing, there is an increasing demand for reliable in-process measurement methods directly on large CNC machine tools, eliminating the need to transport workpieces to metrological laboratories. This study assesses the capability and applicability of an articulated arm coordinate measuring machine and a machine tool touch-trigger probe when measuring to a specified tolerance of 0.05 mm in a production environment. Experiments were conducted using the KOBA calibration standard and included measurements with and without applying the articulated arm coordinate measuring machine leapfrog method. The results were evaluated according to ISO 22514-7:2021 and ISO 14253-1:2017, which establish criteria for measurement system capability. The findings revealed that neither measurement system met the capability requirements of ISO 22514-7:2021, particularly due to unsatisfactory QMS and CMS values. However, under ISO 14253-1:2017, both systems were deemed conditionally suitable for verifying conformity to the specifications, with the articulated arm coordinate measuring machine showing lower applicability when using the leapfrog method. This research supports the idea that unreasonable demands for compliance with current standards may lead to questioning of the systems that previously met older standards. The study contributes to the ongoing discussion on integrating advanced metrological tools into the manufacturing process and underscores the need for careful evaluation to ensure the capability and reliability of measurement systems in industrial practice.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20301 - Mechanical engineering
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Machines
ISSN
2075-1702
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
12
Country of publishing house
CH - SWITZERLAND
Number of pages
27
Pages from-to
„“-„“
UT code for WoS article
001384702000001
EID of the result in the Scopus database
—