Cross-wire Calibration for Freehand 3D Ultrasonography: Measurement and Numerical Issues
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU50147" target="_blank" >RIV/00216305:26220/05:PU50147 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Cross-wire Calibration for Freehand 3D Ultrasonography: Measurement and Numerical Issues
Original language description
3D freehand ultrasound is an imaging technique, which is gradually finding clinical applications. A position sensor is attached to a conventional ultrasound probe, so that B-scans are acquired along with their relative locations. This allows the B-scansto be inserted into a 3D regular voxel array, which can then be visualized using arbitrary-plane slicing, and volume or surface rendering. A key requirement for correct reconstruction is the calibration: determining the position and orientation of the B--scans with respect to the position sensor's receiver. Following calibration, interpolation in the set of irregularly spaced B-scans is required to reconstruct a regular-voxel array. This text describes a freehand measurement of 2D ultrasonic data, an approach to the calibration problem and several numerical issues concerned with the calibration and reconstruction.
Czech name
Kalibrace typu Cross-wire pro 3D Ultrasonografii: měření a numerické problémy
Czech description
3D "freehand" ultrasonografie je zobrazovací technika postupně nacházející klinické aplikace. A position sensor is attached to a conventional ultrasound probe, so that B-scans are acquired along with their relative locations. This allows the B-scans to be inserted into a 3D regular voxel array, which can then be visualized using arbitrary-plane slicing, and volume or surface rendering. A key requirement for correct reconstruction is the calibration: determining the position and orientation of the B-scanns with respect to the position sensor's receiver. Following calibration, interpolation in the set of irregularly spaced B-scans is required to reconstruct a regular-voxel array. This text describes a freehand measurement of 2D ultrasonic data, an approach to the calibration problem and several numerical issues concerned with the calibration and reconstruction.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radioengineering
ISSN
1210-2512
e-ISSN
—
Volume of the periodical
2005
Issue of the periodical within the volume
2
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
222-227
UT code for WoS article
—
EID of the result in the Scopus database
—