Partial Discharges and Acoustic Emission In Insulating Materials

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU51473" target="_blank" >RIV/00216305:26220/05:PU51473 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Partial Discharges and Acoustic Emission In Insulating Materials

  • Original language description

    Partial discharges occur when voltage applied to insulating sheets reaches a critical value which is characteristic for given insulator. The partial discharges are accompanied by acoustic emission events. The acoustic emission signal is measured by a piezoceramic sensor and partial discharges are detected by means of voltage pulses on a load resistance. While a spike of a partial discharge appears immediately, an acoustic event signal is delayed. The time interval depends on the distance of the place whhere partial discharge is created and the wave velocity propagation of an acoustic emission signal. The position of PD source can be estimated for a two channel measuring setup with two AE sensors. The proposed testing method can be used to obtain information on voids, cracks or air bubbles in metal-insulator-metal structures.

  • Czech name

    Částečné výboje a akustická emise v izolantech

  • Czech description

    Partial discharges occur when voltage applied to insulating sheets reaches a critical value which is characteristic for given insulator. The partial discharges are accompanied by acoustic emission events. The acoustic emission signal is measured by a piezoceramic sensor and partial discharges are detected by means of voltage pulses on a load resistance. While a spike of a partial discharge appears immediately, an acoustic event signal is delayed. The time interval depends on the distance of the place whhere partial discharge is created and the wave velocity propagation of an acoustic emission signal. The position of PD source can be estimated for a two channel measuring setup with two AE sensors. The proposed testing method can be used to obtain information on voids, cracks or air bubbles in metal-insulator-metal structures.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    BM - Solid-state physics and magnetism

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2005

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of 3rd Workshop NDT in Progress, International Meeting of NDT Experts

  • ISBN

    80-214-2996-8

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    153-158

  • Publisher name

    Czech Society for Non-destructive Testing

  • Place of publication

    Průhonice

  • Event location

    Praha

  • Event date

    Oct 10, 2005

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article