Dielectric relaxation spectroscopy of KRASOL oligomers
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU51925" target="_blank" >RIV/00216305:26220/05:PU51925 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
čeština
Original language name
Dielektrická relaxační spektroskopie oligomeru KRASOL
Original language description
The objective of this research is to measure and to analyze dielectric properties of KRASOL oligomer materials. The research of material characteristics necessitates the selection of an appropriate analytical method. One of the modern experimental methods is dielectric relaxation spectroscopy (DRS). In general, DRS studies molecular dynamics of current carriers and dipoles. DRS is based on a set of theories and methods dealing with this dynamics. The analysis and subsequent interpretation is based on adetailed observation of temperature dependencies of the relaxation processes prior to and after the ageing process in a broad frequency range. Measurements in the frequency domain were carried out on the Hewlett Packard HP 4284A precision LCR meter using the dielectric test fixture HP 16451B. The sample was analyzed in the temperature chamber, which was specifically developed for this experiment. The position of relaxation maximums matches with the straight-line characteristic and there
Czech name
Dielektrická relaxační spektroskopie oligomeru KRASOL
Czech description
The objective of this research is to measure and to analyze dielectric properties of KRASOL oligomer materials. The research of material characteristics necessitates the selection of an appropriate analytical method. One of the modern experimental methods is dielectric relaxation spectroscopy (DRS). In general, DRS studies molecular dynamics of current carriers and dipoles. DRS is based on a set of theories and methods dealing with this dynamics. The analysis and subsequent interpretation is based on adetailed observation of temperature dependencies of the relaxation processes prior to and after the ageing process in a broad frequency range. Measurements in the frequency domain were carried out on the Hewlett Packard HP 4284A precision LCR meter using the dielectric test fixture HP 16451B. The sample was analyzed in the temperature chamber, which was specifically developed for this experiment. The position of relaxation maximums matches with the straight-line characteristic and there
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Elektrotechnika a informatika 2005, Elektrotechnika
ISBN
80-7043-375-2
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
77-80
Publisher name
Západočeská univerzita v Plzni
Place of publication
Plzeň
Event location
Nečtiny
Event date
Nov 2, 2005
Type of event by nationality
CST - Celostátní akce