Optical System for Position and Orientation Measuring of Ultrasound Probe for 3D Imaging in Cardiology

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU52931" target="_blank" >RIV/00216305:26220/05:PU52931 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21460/05:12110287

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Optical System for Position and Orientation Measuring of Ultrasound Probe for 3D Imaging in Cardiology

  • Original language description

    The fundamental of the described project is an optical position sensing of ultrasound probe in 3D echocardiology, well known as Free-hand system. The project is dealing with multi-camera system, where the probe localization is performed based on different views from the cameras, which are following it (some corresponding marks mounted on the ultrasound probe). The camera calibration and the resolution of the system are evaluated for the specific geometric arrangement as well as the marker recognition allgorithm is described. The described system is an alternative solution to magnetic systems with higher length accuracy, eliminating its disadvantages as e.g. sensitivity on electric conducting materials around.

  • Czech name

    Optical System for Position and Orientation Measuring of Ultrasound Probe for 3D Imaging in Cardiology

  • Czech description

    The fundamental of the described project is an optical position sensing of ultrasound probe in 3D echocardiology, well known as Free-hand system. The project is dealing with multi-camera system, where the probe localization is performed based on different views from the cameras, which are following it (some corresponding marks mounted on the ultrasound probe). The camera calibration and the resolution of the system are evaluated for the specific geometric arrangement as well as the marker recognition allgorithm is described. The described system is an alternative solution to magnetic systems with higher length accuracy, eliminating its disadvantages as e.g. sensitivity on electric conducting materials around.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GP102%2F03%2FD030" target="_blank" >GP102/03/D030: Optical system for position and orientation measuring of ultrasound probe for 3D imaging in cardiology</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2005

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Conference Proceedings of Trends in Biomedical Engineering

  • ISBN

    80-8070-443-0

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    183-187

  • Publisher name

    University of Žilina

  • Place of publication

    Žilina, Slovenská republika

  • Event location

    Žilina

  • Event date

    Jan 1, 2005

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article