Testing the quality of magnetic gradient fields for studying self-diffusion processes in biological specimens by magnetic resonance methods
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU63687" target="_blank" >RIV/00216305:26220/06:PU63687 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Testing the quality of magnetic gradient fields for studying self-diffusion processes in biological specimens by magnetic resonance methods
Original language description
Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on the principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were foundin the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
Czech name
Testování kvality gradientního pole pro měření difůze metodamy Magnetické resonance
Czech description
článek se zaobírá měřenim a posuzováním kvality gradientního pole v MR tomografii pro potřeby měření difůze. Zkoumá chybu meření difůze v závislosti na integrální chybě genetovaného gradientu.
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/KJB208130603" target="_blank" >KJB208130603: Measurement and simulation of material susceptibility and conductivity influences in MR tomography</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2006
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
APCCAS06 proceeding
ISBN
1-4244-0387-1
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
1-4
Publisher name
IEEE
Place of publication
Singapore
Event location
Singapore
Event date
Dec 4, 2006
Type of event by nationality
CST - Celostátní akce
UT code for WoS article
—