All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

DIELECTRIC RELAXATION IN GLYCEROL AT LONG-TIME EXPOSURE TO LOW TEMPERATURE

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F07%3APU68482" target="_blank" >RIV/00216305:26220/07:PU68482 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    DIELECTRIC RELAXATION IN GLYCEROL AT LONG-TIME EXPOSURE TO LOW TEMPERATURE

  • Original language description

    This paper deals with the dielectric relaxation in glycerol at different temperatures (down to 25 K) for protracted periods of time. Two relaxation maxima were observed. The peak at lower frequencies was ascribed to the relaxation ?-process of glycerol proper; the peak at higher frequencies differed in samples from different manufacturers, so that it represents rather a relaxation peak associated with contaminants and not the true ?-process in glycerol. The ?-process was considerably masked by the conductivity component. During a long-time exposure of glycerol to a low constant temperature, the relaxation spectrum shifts with increasing time to lower frequencies, reaching a steady position after about 20 hours.

  • Czech name

    Dielektrická spektra glycerolu při dlouhodobé expozici na nízké teplotě

  • Czech description

    This paper deals with the dielectric relaxation in glycerol at different temperatures (down to 25 K) for protracted periods of time. Two relaxation maxima were observed. The peak at lower frequencies was ascribed to the relaxation ?-process of glycerol proper; the peak at higher frequencies differed in samples from different manufacturers, so that it represents rather a relaxation peak associated with contaminants and not the true ?-process in glycerol. The ?-process was considerably masked by the conductivity component. During a long-time exposure of glycerol to a low constant temperature, the relaxation spectrum shifts with increasing time to lower frequencies, reaching a steady position after about 20 hours.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA102%2F07%2F0113" target="_blank" >GA102/07/0113: Noise as Diagnostic Tool for Schottky and Could Electron Emission Cathodes</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2007

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    6th international conference of phd students

  • ISBN

    978-963-661-783-7

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    379-384

  • Publisher name

    University of Miskolc

  • Place of publication

    Miskolc, Hungary

  • Event location

    Miskolc

  • Event date

    Aug 12, 2007

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article