Portable and Precise Measurements with Interdigital Electrodes at Wide Range of Conductivity
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F07%3APU71135" target="_blank" >RIV/00216305:26220/07:PU71135 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
čeština
Original language name
Portable and Precise Measurements with Interdigital Electrodes at Wide Range of Conductivity
Original language description
A planar structure of the electrodes employed in conductivity measurements is utilizable at small range of conductivity measurement because of small sizes, planar ordering and technology which significantly influence the impedance behavior. The paper presents new approach in the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement using thick-film screen-printed interdigital electrodes (IDEs). Correction characteristics over a wide range of specific conductivities were determined from an interface impedance characterization of the IDEs. A local minimum of the imaginary part of the interface impedance is used for corrections to get linear responses. The method is seeking the optimal frequency for determination of specific conductivity of the solution by IDEs in order to achieve a highly accurate response. The method takes precise conductivity measurements in concentration ranges from 10-6 M to 1 M without
Czech name
Portable and Precise Measurements with Interdigital Electrodes at Wide Range of Conductivity
Czech description
A planar structure of the electrodes employed in conductivity measurements is utilizable at small range of conductivity measurement because of small sizes, planar ordering and technology which significantly influence the impedance behavior. The paper presents new approach in the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement using thick-film screen-printed interdigital electrodes (IDEs). Correction characteristics over a wide range of specific conductivities were determined from an interface impedance characterization of the IDEs. A local minimum of the imaginary part of the interface impedance is used for corrections to get linear responses. The method is seeking the optimal frequency for determination of specific conductivity of the solution by IDEs in order to achieve a highly accurate response. The method takes precise conductivity measurements in concentration ranges from 10-6 M to 1 M without
Classification
Type
D - Article in proceedings
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/1QS201710508" target="_blank" >1QS201710508: Impedimetric chemical microsensors with nanomachined surface of electrodes</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2007
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Elecrtonic Devices and Systems proceedings
ISBN
978-80-214-3470-7
ISSN
—
e-ISSN
—
Number of pages
8
Pages from-to
660-667
Publisher name
Springer
Place of publication
Boston
Event location
Praha
Event date
Sep 12, 2007
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—