Original language description
This paper describes steps involved in a new type of pressure sensing. Significance of this approach and propose approaches for improving sensitivity, resistance to electromagnetic interference, dimensions and accuracy. The main goal of the project is the research of complex smart pressure sensor based on the new sensing system with galvanic fiber optic isolation including research and experimental validation of this new pressure sensing principle. The objectives of the project of applied research are in new methods and technology of pressure sensors with galvanic isolation and function specimen of smart optical pressure sensor for explosive industrial environment and/or environment with high electromagnetic interference and very high precision and absolute resistance to electric and magnetic interference.
Czech name
Návrh teplotně kompenzované kapsle pro optické snímání tlaku
Czech description
This paper describes steps involved in a new type of pressure sensing. Significance of this approach and propose approaches for improving sensitivity, resistance to electromagnetic interference, dimensions and accuracy. The main goal of the project is the research of complex smart pressure sensor based on the new sensing system with galvanic fiber optic isolation including research and experimental validation of this new pressure sensing principle. The objectives of the project of applied research are in new methods and technology of pressure sensors with galvanic isolation and function specimen of smart optical pressure sensor for explosive industrial environment and/or environment with high electromagnetic interference and very high precision and absolute resistance to electric and magnetic interference.
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/FT-TA2%2F087" target="_blank" >FT-TA2/087: Research of new methods of pressure measurement with galvanic isolation for explosive and electromagnetic interferred industrial environment.</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the EDS 08 conference
ISBN
978-80-214-3717-3
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
—
Publisher name
Ing. Zdeněk Novotný CSc.
Place of publication
Brno
Event location
BRNO
Event date
Sep 20, 2007
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—