The Ground Fault Indicators for Fault Location According to the Analysis of Electromagnetic Fields

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU80338" target="_blank" >RIV/00216305:26220/09:PU80338 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Využití indikátorů zemního spojení s detekcí elektromagnetického pole pro lokalizaci zemního spojení

  • Original language description

    The paper is focused on a ground fault location problem in a compensated MV network. For this localization there are used ground fault indicators using electromagnetic fields evaluation of phase conductors or line. These indica-tors are divided into twogroups on the basis of electromag-netic sensors design and both these types of ground indicators are described. Methods which are used by the ground indicators for correct ground fault location are presented and assessed. Fault indication examples of both indicators types are displayed for ground fault on the af-fected line. The sensors of ground fault indicators are installed on MV lines during operation. At present, a test operation in three MV networks with tens of installed indicators is under way.Measuring data are accumulated into the database for future evaluation of the frequent ground fault location in the MV network, it is also possible to assess the type of the ground fault including the prediction of the origination of subs

  • Czech name

    Využití indikátorů zemního spojení s detekcí elektromagnetického pole pro lokalizaci zemního spojení

  • Czech description

    The paper is focused on a ground fault location problem in a compensated MV network. For this localization there are used ground fault indicators using electromagnetic fields evaluation of phase conductors or line. These indica-tors are divided into twogroups on the basis of electromag-netic sensors design and both these types of ground indicators are described. Methods which are used by the ground indicators for correct ground fault location are presented and assessed. Fault indication examples of both indicators types are displayed for ground fault on the af-fected line. The sensors of ground fault indicators are installed on MV lines during operation. At present, a test operation in three MV networks with tens of installed indicators is under way.Measuring data are accumulated into the database for future evaluation of the frequent ground fault location in the MV network, it is also possible to assess the type of the ground fault including the prediction of the origination of subs

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2009

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 10th International Scientific Conference Electric Power Engineering 2009

  • ISBN

    978-80-248-1947-1

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

  • Publisher name

    VSB Ostrava

  • Place of publication

    Ostrava

  • Event location

    Kouty nad Desnou

  • Event date

    May 12, 2009

  • Type of event by nationality

    EUR - Evropská akce