Load Flow Solution

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU80855" target="_blank" >RIV/00216305:26220/09:PU80855 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Load Flow Solution

  • Original language description

    Abstract-load flow solution of HV network is performed. The results are analyzed from the point of view of voltage drops, power losses, line loading. Then a simulation of a partial loss of supply is done and the results are analyzed. It is obvious from the results of load flow solution that current flowing through one line exceeds the line current carrying capacity. That is why an enhancement of the network is proposed. This enhancement consists in adding another line with same parameters in parallel tothat line, which leads to increasing the transmission capacity for the line. Load flow solution of the modified network is performed, both for normal and fault operation. It can be concluded from the results that after adding the enhancing line transmission capacity of all lines is sufficient.

  • Czech name

    Load Flow Solution

  • Czech description

    Abstract-load flow solution of HV network is performed. The results are analyzed from the point of view of voltage drops, power losses, line loading. Then a simulation of a partial loss of supply is done and the results are analyzed. It is obvious from the results of load flow solution that current flowing through one line exceeds the line current carrying capacity. That is why an enhancement of the network is proposed. This enhancement consists in adding another line with same parameters in parallel tothat line, which leads to increasing the transmission capacity for the line. Load flow solution of the modified network is performed, both for normal and fault operation. It can be concluded from the results that after adding the enhancing line transmission capacity of all lines is sufficient.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2009

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    XIV Conference Computer Applications in Electrical Engineering

  • ISBN

    978-83-89333-24-7

  • ISSN

  • e-ISSN

  • Number of pages

    2

  • Pages from-to

  • Publisher name

    COMPRINT AR, Poznan, Poland

  • Place of publication

    Poznan, Poland

  • Event location

    Poznan

  • Event date

    Apr 20, 2009

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article