All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Influence of Parameters on Image Quality Using Fast Spin Echo (FSE) and Comparison with the Conventional Method of Spin Echo (SE)

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU87963" target="_blank" >RIV/00216305:26220/10:PU87963 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Influence of Parameters on Image Quality Using Fast Spin Echo (FSE) and Comparison with the Conventional Method of Spin Echo (SE)

  • Original language description

    The article deals with the effects of parameters TE (echo time), ETL (echo train length) and ETE (effective echo time) in the FSE method. The images are compared in terms of signal / noise ratio (SNR). The importance of these parameters is explained in the article and also is described here algorithm for composing of all data in to k-space before 2-D fast Fourier transform. Measured images are analyzed and we determine the best settings for our sample. Multinuclear spectrometer/ tomograph 4.7 T/200mm was used for this experiment.

  • Czech name

    Influence of Parameters on Image Quality Using Fast Spin Echo (FSE) and Comparison with the Conventional Method of Spin Echo (SE)

  • Czech description

    The article deals with the effects of parameters TE (echo time), ETL (echo train length) and ETE (effective echo time) in the FSE method. The images are compared in terms of signal / noise ratio (SNR). The importance of these parameters is explained in the article and also is described here algorithm for composing of all data in to k-space before 2-D fast Fourier transform. Measured images are analyzed and we determine the best settings for our sample. Multinuclear spectrometer/ tomograph 4.7 T/200mm was used for this experiment.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2010

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 16th Conference Student EEICT 2010 Volume 2

  • ISBN

    978-80-214-4077-7

  • ISSN

  • e-ISSN

  • Number of pages

    3

  • Pages from-to

  • Publisher name

    NOVPRESS s.r.o.

  • Place of publication

    Brno

  • Event location

    FEKT VUT v Brně

  • Event date

    Apr 29, 2010

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article