Measurement of concentration of air ions in the laboratories and cave
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU104949" target="_blank" >RIV/00216305:26220/13:PU104949 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
čeština
Original language name
Measurement of concentration of air ions in the laboratories and cave
Original language description
A gerdien tube (GT) is instrumental towards the measurement of air ions concentration assuming that the volume of tested air has not been limited and the ions are continuously generated. In the time domain, it is possible to measure only ions of one polarity by means of a gerdien tube; then, following a certain interval, ions of the other polarity can be measured. Ionized air is sucked into the gerdien tube by a fan. A homogeneous electric field is set between the inner and the outer electrode. If an electric ion shows a negative electric charge and the collecting inner electrode has a positive electric potential, the ion is progressively attracted to the inner electrode. Provided that the ion impinges upon the electrode, it will induce an electric current that is measured by the help of a sensitive electrometric picoampermeter. The velocity of the ions motion in the electric field can be described by mobility k [ m2*V-1*s-1].
Czech name
Measurement of concentration of air ions in the laboratories and cave
Czech description
A gerdien tube (GT) is instrumental towards the measurement of air ions concentration assuming that the volume of tested air has not been limited and the ions are continuously generated. In the time domain, it is possible to measure only ions of one polarity by means of a gerdien tube; then, following a certain interval, ions of the other polarity can be measured. Ionized air is sucked into the gerdien tube by a fan. A homogeneous electric field is set between the inner and the outer electrode. If an electric ion shows a negative electric charge and the collecting inner electrode has a positive electric potential, the ion is progressively attracted to the inner electrode. Provided that the ion impinges upon the electrode, it will induce an electric current that is measured by the help of a sensitive electrometric picoampermeter. The velocity of the ions motion in the electric field can be described by mobility k [ m2*V-1*s-1].
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
International Interdisciplinary PhD Workshop 2013, Proceedings
ISBN
978-80-214-4759-2
ISSN
—
e-ISSN
—
Number of pages
5
Pages from-to
182-186
Publisher name
Neuveden
Place of publication
Brno, Czech republic
Event location
Brno
Event date
Sep 8, 2013
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—