All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Partial discharge detection and localization system

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F14%3APU110613" target="_blank" >RIV/00216305:26220/14:PU110613 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Partial discharge detection and localization system

  • Original language description

    This article describes the partial discharges (PD) detection and localization system. Localization can be performed on the basis of measured UHF waveforms analysis during activity of the partial discharges. The time-shifts of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in the 3D space a minimum of four antennas has to be used, since the time of the PD is unknown. Analysis of the PD starts with visual investigation of the signals present inside of the power oil transformer. PD signal level is in comparison to other signals inside the transformer very low. Therefore, signal line contains, except amplifiers, also controlled attenuators to reach required trigger conditions. Detailed investigation of all signals inside transformer is provided in memory mode in which system store defined number of signals for offline diagnosis a localization. Continual and memory mode of the system also contain discrimination method for non PD signals removing. Discrimination method is based on simultaneous detection of the signal inside and outside of the transformer with aim to acquire only signal which comes from inside of the transformer. Localization of the PD origin is based on TDOA and matrix algorithm. Resulting position are visualized as point in transformer 2D and 3D scheme.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Progress in Electromagnetics Research Symposium 2014, Guangzhou

  • ISBN

    978-1-934142-28-8

  • ISSN

    1559-9450

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    2344-2349

  • Publisher name

    Neuveden

  • Place of publication

    Neuveden

  • Event location

    Guangzhou

  • Event date

    Aug 25, 2014

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000393225900520