The Comparison of different types of Spectroradiometers in terms of Uncertainty of measurement
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F17%3APU124977" target="_blank" >RIV/00216305:26220/17:PU124977 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
The Comparison of different types of Spectroradiometers in terms of Uncertainty of measurement
Original language description
This article describes and compares different types of spectroradiometers in terms of uncertainty of measurement of spectral power distribution. Measurement of spectral power distribution is important for evaluation of main photometric quantities. In order to compare different types of spectroradiometers, it is used scanning spectroradiometer with single detector and double monochromator as reference. Although uncertainty of the measurement of spectroradiometer is known, there are complications with measuring narrow spectral peaks. With small bandwidth it is possible to measure narrow peaks correctly. However with wider bandwidth the measured peaks are more widespread. Thus compact array spectroradiometers can be used for measuring light sources with wide spectrum without peaks. However for measuring discharge lamps and LED with narrow spectrum with acceptable uncertainty of measurement it is necessary to use single or double slit monochromator. Next task is focused on testing spectral accuracy of different spectroradiometers. Spectral shift can influence calculated photometric quantities.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20704 - Energy and fuels
Result continuities
Project
<a href="/en/project/LO1210" target="_blank" >LO1210: Energy for Sustainable Development</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
PROCEEDINGS of the Lux Europa 2017 Conference
ISBN
978-961-93733-4-7
ISSN
—
e-ISSN
—
Number of pages
5
Pages from-to
684-688
Publisher name
Neuveden
Place of publication
Neuveden
Event location
Ljubljana
Event date
Sep 18, 2017
Type of event by nationality
EUR - Evropská akce