Asymmetric bipolar electrochemistry: Detailed empirical description and determination of output characteristics of a galvanic system with multiple short-circuited cells in one electrolyte
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F19%3APU131847" target="_blank" >RIV/00216305:26220/19:PU131847 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14310/19:00110356 RIV/00216275:25310/19:39915890
Result on the web
<a href="http://dx.doi.org/10.1016/j.electacta.2019.03.209" target="_blank" >http://dx.doi.org/10.1016/j.electacta.2019.03.209</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2019.03.209" target="_blank" >10.1016/j.electacta.2019.03.209</a>
Alternative languages
Result language
angličtina
Original language name
Asymmetric bipolar electrochemistry: Detailed empirical description and determination of output characteristics of a galvanic system with multiple short-circuited cells in one electrolyte
Original language description
It is empirically expected that if two galvanic cells are inserted in a single electrolyte cell, their output parameters will not be enhanced due to the internal (electrolyte) short circuit. Our previous concept of a galvanic cell with a galvanic short circuit (GSC) in a thin-layer arrangement disproved this expectation. Here, the system with GSC was studied in depth, described and an empiric model was derived and confirmed experimentally. The crucial influence of the solution and the charge transfer resistances on the output performance of the cell were observed. A set of galvanic cells was prepared using screen-printing. The panel of galvanic cells was designed and prepared in a way which enabled simple modular combination of more than one GSC. Thus, multiples of the voltage of the initial single cell can be obtained, while using only scissors for cutting the desired shape of the cell. The output characteristics under load were determined in a bulk measurement. Although, the enhancement of the output voltage in such experimental setup was not as pronounced as in a thin layer, the cell with GSC performed better in comparison with a single galvanic cell.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electrochimica Acta
ISSN
0013-4686
e-ISSN
1873-3859
Volume of the periodical
1
Issue of the periodical within the volume
207
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
269-274
UT code for WoS article
000464956000028
EID of the result in the Scopus database
2-s2.0-85064228958