All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU134651" target="_blank" >RIV/00216305:26220/20:PU134651 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S014206151932068X?dgcid=author" target="_blank" >https://www.sciencedirect.com/science/article/pii/S014206151932068X?dgcid=author</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.ijepes.2019.105768" target="_blank" >10.1016/j.ijepes.2019.105768</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers

  • Original language description

    The paper presents a new approach for earth fault localization which is based on evaluation of phase to ground voltages recorded by voltage monitors installed at low-voltage side of distribution transformer station deployed under smart metering projects. The introduced method "Vdip" determines the probability of asymmetrical fault location based on comparison of the changes in negative sequence current recorded at the feeding medium voltage substation and changes in negative sequence voltages recorded at the LV sides of distribution transformers. The paper describes the nature of the method and presents its principle using simulation of a MV resonant earthed distribution network where short-term connection of an auxiliary resistor is used. The method was also evaluated in real resonant earthed 22 kV network, where totally 15 earth faults with fault resistance up to 1.2 k Omega were carried out. As the result of this field test, the location error of the Vdip method is presented.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS

  • ISSN

    0142-0615

  • e-ISSN

    1879-3517

  • Volume of the periodical

    118

  • Issue of the periodical within the volume

    118

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

    000518691600020

  • EID of the result in the Scopus database

    2-s2.0-85076829505