Testing of the Faulty Phase Earthing System Using Real-Time Simulator

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F22%3APU145536" target="_blank" >RIV/00216305:26220/22:PU145536 - isvavai.cz</a>

  • Result on the web

    <a href="https://eesymp.fei.tuke.sk/viewabstract.php?id=21" target="_blank" >https://eesymp.fei.tuke.sk/viewabstract.php?id=21</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Testing of the Faulty Phase Earthing System Using Real-Time Simulator

  • Original language description

    To extinguish arc of a single-phase fault in resistor earthed distribution networks, an automatic reclosing system is usually used. However, this operation results in a short-term power supply interruption. As an alternative to the automatic reclosing function, it is possible to apply a faulty phase earthing (FPE) system. The main objective of this paper is to test the faulty phase earthing system using the real-time digital simulator (RTDS) environment, where behaviour of a real distribution network will be numerically simulated. One of the advantages of the real-time testing is the possibility to bring the output of the protection device (i.e. the input for the faulty phase earthing or triggering the circuit breaker operation) back to the simulation and, therefore, test the hardware in the loop. As a test object, the ABB feeder protection is used. This device is programmed according to the defined requirements of the FPE algorithm. The aim is to prove proper functionality of the algorithm and its correct implementation into the protection terminal settings, which is crucial for securing high reliability of the FPE system prior its installation to real resistor earthed network. The paper is focused on verification of the FPE system prior its real application in pilot test as alternative to autoreclosing system in real resistor earthed distribution network.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/TK01030094" target="_blank" >TK01030094: Smart Energy Network (SEN)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 11th International Scientific Symposium on Electrical Power Engineering, ELEKTROENERGETIKA 2022

  • ISBN

    978-80-553-4104-0

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    246-250

  • Publisher name

    Technical University of Košice

  • Place of publication

    Košice

  • Event location

    Stará Lesná

  • Event date

    Sep 12, 2022

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article