New Insights into the Comprehensive System of Thermodynamic Sensors and Electronic Nose and Its Practical Applications in Dough Fermentation Monitoring
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F24%3APU150050" target="_blank" >RIV/00216305:26220/24:PU150050 - isvavai.cz</a>
Alternative codes found
RIV/70883521:28110/24:63578844 RIV/70883521:28140/24:63578844 RIV/70883521:28610/24:63578844
Result on the web
<a href="https://www.mdpi.com/1424-8220/24/2/352" target="_blank" >https://www.mdpi.com/1424-8220/24/2/352</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s24020352" target="_blank" >10.3390/s24020352</a>
Alternative languages
Result language
angličtina
Original language name
New Insights into the Comprehensive System of Thermodynamic Sensors and Electronic Nose and Its Practical Applications in Dough Fermentation Monitoring
Original language description
This study focuses on an applicability of the device designed for monitoring dough fermentation. The device combines a complex system of thermodynamic sensors (TDSs) with an electronic nose (E-nose). The device’s behavior was tested in experiments with dough samples. The configuration of the sensors in the thermodynamic system was explored and their response to various positions of the heat source was investigated. When the distance of the heat source and its intensity from two thermodynamic sensors changes, the output signal of the thermodynamic system changes as well. Thus, as the distance of the heat source decreases or the intensity increases, there is a higher change in the output signal of the system. The linear trend of this change reaches an R2 value of 0.936. Characteristics of the doughs prepared from traditional and non-traditional flours were successfully detected using the electronic nose. To validate findings, the results of the measurements were compared with signals from the rheofermentometer Rheo F4, and the correlation between the output signals was closely monitored. The data after statistical evaluation show that the measurements using thermodynamic sensors and electronic nose directly correlate the most with the measured values of the fermenting dough volume. Pearson’s correlation coefficient for TDSs and rheofermentometer reaches up to 0.932. The E-nose signals also correlate well with dough volume development, up to 0.973. The data and their analysis provided by this study declare that the used system configuration and methods are fully usable for this type of food analysis and also could be usable in other types of food based on the controlled fermentation. The system configuration, based on the result, will be also used in future studies.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
21101 - Food and beverages
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
SENSORS
ISSN
1424-8220
e-ISSN
1424-3210
Volume of the periodical
24
Issue of the periodical within the volume
2
Country of publishing house
CH - SWITZERLAND
Number of pages
15
Pages from-to
1-15
UT code for WoS article
001151180300001
EID of the result in the Scopus database
2-s2.0-85183324351