Comparison and recommendations on earthing system measurement and simulation techniques including staged fault method

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0199401" target="_blank" >RIV/00216305:26220/26:0199401 - isvavai.cz</a>

  • Result on the web

    <a href="https://digital-library.theiet.org/doi/pdf/10.1049/icp.2025.2112?download=true" target="_blank" >https://digital-library.theiet.org/doi/pdf/10.1049/icp.2025.2112?download=true</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1049/icp.2025.2112" target="_blank" >10.1049/icp.2025.2112</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison and recommendations on earthing system measurement and simulation techniques including staged fault method

  • Original language description

    The article introduces the results of thorough measurement of an earthing system in 22 kV compensated network in comparison to the staged fault. A variety of measurements have been carried out including the staged fault, Wenner soil resistivity measurement, 62 % earth resistance measurement with low and high injecting current, touch voltages and potential distribution. A mathematical model of the earthing system was modelled to obtain the theoretical results and compare them with measurements. The aim of measurements was to investigate the impact of high injecting current on the earth resistance measurement. However, a discrepancy was found out leading to possible cause being the discontinuity of the earthing system or uncertainty of actual earthing system design as well as other possible causes. The helpfulness and complementation of each different method is demonstrated while the root cause of the observed discrepancy is investigated. Unfortunately, based on the results it cannot be ruled out whether it can be beneficial to carry out the measurement with high injecting current. However, the results seem to be on a safe side, meaning that conducting the measurement of earth resistance with low current leads to safer designs.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    IET Conference Proceedings

  • ISBN

  • ISSN

  • e-ISSN

    2732-4494

  • Number of pages

    5

  • Pages from-to

    2454-2458

  • Publisher name

    Institution of Engineering and Technology (IET)

  • Place of publication

    Geneva, Switzerland

  • Event location

    Ženeva

  • Event date

    Jun 16, 2025

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article